Property | Value |
---|---|
Promotion Restriction | Not eligible for promotion |
Item | Safety Interlock 300Vac 5A Txcs |
Height | 146-146 mm |
Width | 98 mm |
Depth | 44 mm |
Material | metal |
Head Material | zamak |
Standards | EN/IEC 60204-1 || EN/IEC 60947-5-1 || EN 1088/ISO 14119 || EN/ISO 12100 || UL 508 || CSA C22.2 No 14 |
Electrical Connection | terminal 1 x 0.5...2 x 1.5 mm? with or without cable end |
Body Material | zamak |
Mechanical Durability | 1000000 cycles |
Shock Resistance | 10 gn 11 ms IEC 60068-2-27 |
Vibration Resistance | 5 gn 10-500 Hz)IEC 60068-2-6 |
Head Type | key operated turret head |
[Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-5-1 |
Cable Entry | 2 entries tapped Pg 13.5 |
Signalling Circuit Type | AC/DC |
Protective Treatment | TC |
[Ie] Rated Operational Current | 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 |
Maximum Actuation Speed | 0.5 m/s |
Positive Opening | with NC contact |
Ip Degree Of Protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |
Signalling Circuit Voltage | 24/48 V 20...52 V) |
Electrical Shock Protection Class | class I EN/IEC 61140 |
Electromagnet Interlocking | locking on de-energisation and unlocking on energisation of solenoid |
Product Or Component Type | safety switch |
Ambient Air Temperature For Storage | -40-70°C |
Component Name | XCSE |
Maximum Operating Rate | 10 cyc/mn for maximum durability |
Contacts Type And Composition | 2 NC + 1 NO |
Protection Type | overvoltage protection signalling circuit |
Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
Signalling Circuit Consumption | 7 mA |
Cable Outer Diameter | 9-12 mm |
Safety Level | can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Ambient Air Temperature For Operation | -25-40°C |
Contact Operation | slow-break, break before make |
Supply Voltage Type | AC/DC |
Local Signalling | for guard open/guard closed and locked 2 LEDs (green or orange) |
Design | rectangular |
[Ui] Rated Insulation Voltage | 50 VEN/IEC 60947-1 signalling circuit |
Number Of Poles | 3 |
Supply Frequency | 50/60 Hz |
Minimum Actuation Speed | 0.01 m/s |
Minimum Actuator Force For Extraction | 20 N |
[Us] Rated Supply Voltage | 24 V - 20...10 % |
Load Factor | 1 |
[Ithe] Conventional Enclosed Thermal Current | 6A |
Power Consumption In Va | 10 VA inrush || 10 VA sealed |
Solenoid Contacts Type And Composition | 1 NC + 1 NO slow-break, simultaneous) |
Product Certifications | UL || CSA |
Actuator Forcible Withdrawal Rtc | 2000 N |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
Safety Interlock 300Vac 5A Txcs, TELEMECANIQUE SENSORS, Mfr# XCSE7311
$537.39
Free shipping will be applied on orders over $50
Safety Interlock 300Vac 5A Txcs
Out of stock
You must be logged in to post a review.