Control Unit cl103Ph 1255A 24Vdc, SCHNEIDER ELECTRIC, Mfr# LUCB05BL

$154.99

Free shipping will be applied on orders over $50

Advcntrlunitcl103Ph 1255A 24Vdc

Out of stock

Brand Name: SCHNEIDER ELECTRIC
Mfr #: LUCB05BL
Availability: Ships in 7 days
SKU: GRG0561736
UPC: 785901222064
Category:

Analogues

PropertyValue
ItemAdvcntrlunitcl103Ph 1255A 24Vdc
Overload Relay Amp Setting1.25 to 5 A
Coil Volts24V DC
FeaturesProtection against overload and short-circuit, Manual reset, Earth fault protection, Protection against phase failure and phase imbalance, Free of Halogen, Mercury u0026 Pvc, Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock u0026 Vibration
Width45 mm
Hz40 to 60 Hz
Depth60 mm
StandardsEN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier, CE, CCC, EAC, ASEFA, ATEX, Marine
Height66 mm
Operating Voltage690V AC
Ambient Air Temperature For Storage-40 to 185°F (-40 to 85°C)
Immunity To Microbreaks3 ms
Typical Current Consumption130 mA 24 V DC I maximum while closing with LUB12, 220 mA 24 V DC I maximum while closing with LUB32, 220 mA 24 V DC I maximum while closing with LUB38, 60 mA 24 V DC I rms sealed with LUB12, 80 mA 24 V DC I rms sealed with LUB32, 80 mA 24 V DC I rms sealed with LUB38
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
Load Type3-phase motor self-cooled
Product NameTeSys Ultra
Fixing ModePlug-in front face)
Phase Failure SensitivityYes
Device ApplicationMotor control, Motor protection
Vibration Resistance2 gn 5 to 300 Hz power poles open IEC 60068-2-6, 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6
Fire Resistance1760°F (960°C) parts supporting live components IEC 60695-2-12, 1202°F (650°C) IEC 60695-2-12
Immunity To Voltage Dips70% / 500 ms IEC 61000-4-11
Shock Resistance10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
Operating Altitude6561.68 ft (2000 m)
Product CompatibilityPower base LUB12, Power base LUB32, Power base LUB38, Power base LUB120, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B12BL, Reversing contactor breaker LU2B32BL, Reversing contactor breaker LU2B38BL
Thermal Overload ClassClass 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) IEC 60947-6-2, Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) UL 508
Rated Insulation Voltage690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
Rated Operational Voltage690 V AC
Product Or Component TypeAdvanced control unit
ResetManual reset
Main Function AvailableProtection against overload and short-circuit, Manual reset, Earth fault protection, Protection against phase failure and phase imbalance
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Protective TreatmentTH IEC 60068
IP Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1, IP40 front panel outside connection zone IEC 60947-1
Resistance To Radiated Fields9.14 V/m (10 V/m) 3 IEC 61000-4-3
Product Specific ApplicationBasic protection and advanced functions, communication
Immunity To Radioelectric Fields10 V IEC 61000-4-6
Heat Dissipation2 W control circuit with LUB12, 3 W control circuit with LUB32, 3 W control circuit with LUB38
Motor Power KW1.5 kW 400 to 440 V AC 50/60 Hz, 2.2 kW 500 V AC 50/60 Hz, 3 kW 690 V AC 50/60 Hz
Control Circuit Voltage24 V DC
Control Circuit Voltage Limits20 to 27 V DC 24 V in operation, 14.5 V DC 24 V drop-out
Operating Time35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 70 ms closing with LUB12 control circuit, 70 ms closing with LUB32 control circuit, 70 ms closing with LUB38 control circuit
Ambient Air Temperature For Operation-13 to 158°F (-25 to 70°C)
Tripping Threshold14.2 x Ir +/- 20%
Utilisation CategoryAC-44, AC-41, AC-43
Product CertificationsCE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
Compatibility CodeLUCB
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#Control Unit cl103Ph 1255A 24Vdc
#SCHNEIDER ELECTRIC
#Mfr LUCB05BL
#SCHNEIDER ELECTRIC
#GRG0561736
#mfr:LUCB05BL
#part number:LUCB05BL
#pn:LUCB05BL
#part code:LUCB05BL
#item number:LUCB05BL
#product code:LUCB05BL
#manufacturer number:LUCB05BL
#manufacturers part number:LUCB05BL
#mfn:LUCB05BL

Reviews

There are no reviews yet.

Add a review