Property | Value |
---|---|
Phase - Electrical | Three |
Input Voltage - Transformer | 480V AC Delta |
Output Voltage - Transformer | 120V AC, 208V AC Wye |
Item - Transformer | Three Phase Transformer |
VA Rating - Transformer | 225 kVA |
Mounting - Transformer | Floor |
Outdoor Rated - Transformer | No |
Temp. Rise | 150 Degrees C |
Winding Material - Transformer | Aluminum |
Hz - Electrical | 60 Hz |
VA Rating | 225kVA |
Hz | 60 |
Height | 57.5 in |
Voltage Function - Transformer | Step Down |
Input Voltage | 480VAC |
Depth | 32.75 in |
Mounting | Floor |
Enclosure Rating | NEMA 1 (Convertible to NEMA 3R by Adding Weather Shield) |
Output Voltage | 208VAC Wye/120VAC |
Enclosure Type | Indoor |
Knockout Size - Transformer | No Knockout |
Width | 40.07 in |
Item | Three Phase Transformer |
Standards | NEMA ST-20, UL Listed |
Mounting - Transformer | Floor |
Phase | 3 phase |
Material | aluminium |
Continuous Thermal Current Rating Factor | 1451.2286916602 16.6 % || 1984.8003496249999 25 % || 4847.8007465 50 % || 9619.468074625 75 % || 16299.802333999998 1.0 % |
Degree Of Protection | UL type 1 || UL type 2, with 7400DS25J || UL type 3R, with 7400WS25J |
Temperature Rise | 220°C insulated || 150°C |
Network Frequency | 60 Hz |
Percentage Reactance | 0.000388 |
[Ipk] Rated Peak Withstand Current | 14.3 kA |
Efficiency | 99.06 % at 35 % load factor , 75.0°C |
Transformer Type | energy efficient |
Type Of Cooling | natural convection |
Rated Operational Power In Va | 225 kVA |
Mounting Support | floor || floor, with 7400FMB |
Product Or Component Type | transformer |
Secondary Voltage | 208Y/120 V |
Tap Loss | 302.0 no load (core loss) || 4475.0 load loss (coil loss) |
Device Short Name | DOE 2016 |
Noise Level | 6 dB NEMA ST-20 || 49 dB |
Average Ambient Air Temperature For Operation | 30°C |
Ambient Air Temperature For Operation | 40-40°C |
[Uimp] Rated Impulse Withstand Voltage | 10 kV |
Primary Voltage | 480 V delta |
Number Of Tap-Offs | 2 2.5 % FCAN || 4 2.5 % FCBN |
Device Application | low voltage electrical distribution |
Percentage Impedance Voltage | 0.044 |
X/R Ratio | 1.95 |
Electrical Connection | 4 Hole Nema Pad primary 11.1 mm || 6 Hole Nema Pad secondary 11.1 mm || 8 Hole Nema Pad sec - XO 11.1 mm |
Sound Level | 6 dB NEMA ST-20, 49 dB |
Transformer Losses | 302.0 no load (core loss), 4475.0 load loss (coil loss) |
Transformer Btu/Hr | 1451.2286916602 16.6%, 1984.8003496249999 25%, 4847.8007465 50%, 9619.468074625 75%, 16299.802333999998 1.0% |
Box Number | 25J |
DOE Efficiency | 99.06% at 35% load factor , 167°F (75.0°C) |
Country of Origin (subject to change) | Mexico |
Package Quantity | 1 |
Three Phase Transformer, 225kVA, 480VAC, SQUARE D, Mfr# EX225T3H
$11442.99
Free shipping will be applied on orders over $50
Three Phase Transformer, Input Voltage - Transformer 480V AC Delta, Output Voltage - Transformer 120V AC, 208V AC Wye, VA Rating - Transformer 225 kVA, Mounting - Transformer Floor, Outdoor Rated - Transformer No, Voltage Function - Transformer Step Down, Winding Material - Transformer Aluminum, Hz - Electrical 60 Hz, Temp. Rise 150 Degrees C, Enclosure Rating NEMA 1 (Convertible to NEMA 3R by Adding Weather Shield)
Out of stock
You must be logged in to post a review.
Reviews