IEC Magnetic Contactor, 3 Poles, 48 to 130 V AC/DC, 40 A, Reversing: Yes, Schneider Electric, Mfr#: LC2D40AEHE

$334.99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 48-130V AC/DC, Number of Poles 3, Full Load Current - Inductive 40 A, Full Load Current - Resistive 60 A, Reversing Capability Reversing, Overall Height 4.8 in, Overall Width 4.69 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

Out of stock

Brand Name: Schneider Electric
Mfr #: LC2D40AEHE
Availability: Ships in 53 days
SKU: GRG6032877 Category:

Analogues

PropertyValue
ItemIEC Magnetic Contactor
Full Load Amps-Inductive40 A
Full Load Amps-Resistive60 A
Number of Poles3
Coil Volts48 to 130 V AC/DC
ReversingYes
HP @ 1 Phase - 120V3 hp
HP @ 1 Phase - 240V5 hp
Height4.8 in
HP @ 3 Phase - 208V10 hp
Width4.69 in
Depth4.72 in
HP @ 3 Phase - 575V30 hp
HP @ 3 Phase - 240V10 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V30 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Frame / Series / Class / CodeTeSys
StandardsCCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1
SeriesTeSys Deca
NEMA SizeNot Applicable
Auxiliary Contact Form1NO/1NC
IP RatingIP20
Mounting StyleDIN Rail, Plate
Horsepower @ Three Phase - 208V AC10 hp
Horsepower @ Three Phase - 240V AC10 hp
Embedded Surge SuppressorNo
Electrical Operating Durability2,000,000, 700,000
Overall Height4.8 in
Horsepower @ Single Phase - 120V AC3 hp
Full Load Current - Inductive40 A
Overall Depth4.72 in
Horsepower @ Three Phase - 480V AC30 hp
Frequency50/60 Hz
Resistance PropertiesFire Resistant, Insulation Resistant
Overall Width4.69 in
Terminal Connection TypeScrew Clamp Terminals
Horsepower @ Single Phase - 240V AC5 hp
Horsepower @ Three Phase - 600V AC30 hp
Full Load Current - Resistive60 A
Includes Auxiliary ContactsYes
Minimum Operating Temperature-40 Degrees F
Mechanical Operating Durability6,000,000
Maximum Operating Temperature140 Degrees F
Number of Normally Open Main Contacts3
NEMA Enclosure MaterialNot Applicable
Number of Auxillary Contacts2
Maximum Voltage Rating690V AC
NEMA Enclosure RatingNo Enclosure
Coil Voltage48-130V AC/DC
Reversing CapabilityReversing
Contactor StyleIEC
Tightening Torque1.7 Nm (Control Circuit), 5 to 8 Nm (Power Circuit)
Inrush VA23 VA
Working HeightUp to 9842.52 ft
Mechanical Durability6 Mcycles
Switching Voltage17 V (Signalling Circuit)
ApplicationMotor Control, Resistive Load
Signalling Circuit Frequency25 to 400 Hz
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Hold VA1.4 VA
Environmental AttributesMercury Free, Pollution Degree 3
Includes Protective CoverYes
Operating Time55 to 65 ms (Closing), 20 to 120 ms (Opening)
Net Weight2.154 kg
Operating Speed3600 cycles per hr
Rated Breaking Capacity800 A @ 440V
Fuse Amps10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit)
Impedance1.5 mOhm
Thermal Amperage10 A (at 60°C Signalling Circuit), 60 A (at 60°C Power Circuit)
Rated Insulation Volts690V
Non-Overlap Time1.5 ms
Overvoltage CategoryCAT III
Fire RatingUL 94 V1
Electrical Durability2 Mcycles (35 A, AC-3, Less than 440 V); 0.7 Mcycles (60 A, AC-1, Less than 440 V)
Impulse Withstand Voltage6 kV
Max. Operating Watts11 kW (at 220 to 230V AC 50 Hz), 18.5 kW (at 380 to 400V AC 50 Hz), 22 kW (at 415V AC 50 Hz), 22 kW (at 440V AC 50 Hz), 22 kW (at 500V AC 50 Hz), 30 kW (at 660 to 690V AC 50 Hz)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Switching Current5 mA (Signalling Circuit)
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit)
Control Circuit Voltage LimitsDrop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C); Operational AC/DC: 0.85 to 1.1 Uc (at -40 to 60°C), 1 to 1.1 Uc (at 60 to 70°C)
Mounts OnPlate, Rail
Rated Voltage690V AC
Max. Temperature850°C
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Rated Short-Time Withstand Current100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit), 320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit)
Watts Loss0.9W
Electrical ConnectionControl Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors
FeaturesBuilt-In Bi-Directional Peak Limiting; Preassembled with Reversing Power Busbar
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#48 to 130 V AC/DC
#40 A
#Reversing: Yes
#Schneider Electric
#Mfr: LC2D40AEHE
#Schneider Electric
#GRG6032877
#mfr:LC2D40AEHE
#part number:LC2D40AEHE
#pn:LC2D40AEHE
#part code:LC2D40AEHE
#item number:LC2D40AEHE
#product code:LC2D40AEHE
#manufacturer number:LC2D40AEHE
#manufacturers part number:LC2D40AEHE
#mfn:LC2D40AEHE

Reviews

There are no reviews yet.

Add a review